Case 6

A split (broken) shift with two runs and no breaks in either run.


Diagram showing a color-coded version of the described shift.
Abbr
Short abbreviation for the name.
Description
Shift description that will help you keep in mind what kind of shift it is.
Split
Check this box.
Garage
If you leave this blank, the shift can be associated with any garage at the time that a runcut job is submitted. If you want this shift to be associated only with a specific garage, select the garage from which this shift will operate.
Min Runs
Optional. Minimum number or percent of shifts of this type.
Max Runs
Optional. Maximum number or percent of shifts of this type.

First Run

Earliest First signon
Enter a value if a run must start no earlier than this time. Typically, this is left blank.
Latest First signon
Enter a value if a run must start no later than this time. Typically, this is left blank.
Earliest First signoff
Enter a value if a run must end no earlier than this time. Typically, this is left blank.
Latest First signoff
Enter a value if a run must end no later than this time. Typically, this is left blank.
First Run Min

Minimum time of the first run from sign-on to sign-off.

First Run Max

Maximum time of the first run from sign-on to sign-off.

Earliest Break

Leave blank.

Latest Break

Leave blank.

Second Run

Earliest Second signon
Enter a value if second run must start no earlier than this time. Typically, this is left blank.
Latest Second signon
Enter a value if the second run must start no later than this time. Typically, this is left blank.
Earliest Second signoff
Enter a value if the second run must end no earlier than this time. Typically, this is left blank.
Latest Second signoff
Enter a value if the second run must end no later than this time. Typically, this is left blank.
Second Run Min
Minimum time of the second run from sign-on to sign-off.
Second Run Max
Maximum time of the second run from sign-on to sign-off.
Second earliest Break
Leave blank.
Second latest Break
Leave blank.
Min Spread
Minimum allowed time from sign-on to sign-off.
Max Spread
Maximum allowed time from sign-on to sign-off.
Min Gap
Minimum time between the sign-off of the first run and the sign-on of the second run in the shift.
Max Gap
Maximum time between the sign-off of the first run and the sign-on of the second run in the shift.
Main Break Time
Leave blank.
Extra Break Time
Leave blank.
Extra Piece Min
Leave blank.
Extra Piece Max
Leave blank.
Larger Shift
Leave blank.